603 Vicat heat distortion tester is manufactured by Tinius Olsen's latest digital control automatic heat distortion Vicat, can simultaneously test six samples according to the parameters set by the user.
   603 Vicat heat distortion by the part of the oil bath, workstations and handheld input / output terminals and other components, the type and number of workstations to be chosen, the heat distortion temperature workstations span of 100mm and 64mm two tranches. In addition, 603 Vicat heat distortion can also be connected to a computer using the HDV software to set test parameters, output test report and store test results.
   603 Vicat heat distortion analyzer equipped with a pneumatic lifting platform, using the keys on the handheld terminal can operate all workstations free lift, easy to replace the sample.
   Automatic testing process conducted by the computer once or run HDV handheld terminal software to begin testing, the testing process can be fully automated test according to user input parameters. After the testing process, automatic cooling to the starting temperature, in order to facilitate the next test.
   Test parameters can be entered via a handheld terminal or a computer running the software HDV, including the type of test, the support span, sample size, load, etc., can also set the initial temperature, soak time, heating rate and maximum temperature oil bath parameters, these parameters can be stored and used for subsequent testing.
   603 built-in radiator heat distortion Vicat automatically switched on after the end of the test cooling water for cooling, silicone oil can be reduced to a temperature above the cooling water inlet temperature of 20 ℃ from 300 ℃ within 20 minutes.
   After the cooling process, lifting platform automatically rises, easy to replace the sample, the sample may be accidentally dropped salvage salvaged from the net, keep clean silicone oil.
   The computer HDV handheld terminal and run the software can display a continuous curve of each workstation temperature and deformation amount.
HDV software
1. convenient to use a computer to test control and data storage
2. The user can freely choose the format of the test report
3. Built-in SPC program ......
4. Test the temperature and the amount of deformation during the real-time display
5. Test mode can be set under the parameters, run the test and store test results
Browse mode under 6. Recall previous test results and maintenance of the database
At 7. Demo mode for hands-on training
8. The two permissions password protection system


Technical Parameters:
 
Temperature range: 23 ~ 300 ℃
Heating rate: 50 ℃ / Hour or 120 ℃ / Hour
Temperature display accuracy: 0.1 ℃
Temperature sensors: Each workstation independent sensors
Deformation sensors: LVDT
Deformation sensor display accuracy: 0.001mm
Cooling rate: cooling to a temperature above the cooling water within 20 minutes 20 ℃
Overtemperature protection limit: oil bath and software setup dual role
Dimensions: 965X695X560mm
Weight: 115Kg
Heat transfer medium: 14 liters of silicone oil
Source: cooling water
Compressed air: dry compressed air 40psi (2.7bar)
Power: 50 / 60Hz single-phase 220 ± 10% V power supply, 4.5kW


main feature:
 
1. Meet the GB / T1633, GB1634, ISO75, ISO306, ASTM D648, ASTM D1525 and other standards
2. Fully automatic testing process
3. with the exhaust fan air vents, exhaust fumes
3. The use of air bearings to reduce friction
4. The amount of deformation sensor accuracy 0.001mm
5. workstation itself a load of 76g
6. Built-rapid cooling radiator
7. The pneumatic lift station, easy to replace the sample
8. The temperature compensation technology, the instrument itself for the deviation due to temperature changes caused by the automatic correction
9. Built-in fishing nets, fishing dropped sample
10. A variety of options: Workstation, thermal deformation head, Vicat needle pressure, weight, 64mm span support, etc.

 